table 1: main features description available in high power packages, the bta/ btb40-41 series is suitable for general purpose ac switching. they can be used as an on/off function in applications such as static relays, heat- ing regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers, ... thanks to their clip assembly technique, they provide a superior performance in surge current handling capabilities. by using an internal ceramic pad, the bta series provides voltage insulated tab (rated at 2500v rms ) complying with ul standards (file ref.: e81734). symbol value unit i t(rms) 40 a v drm /v rrm 600 and 800 v i gt (q 1 ) 50 ma 40a triac s table 2: order codes part number marking bta40-xxxb see table 8 on page 6 bta41-xxxbrg btb41-xxxbrg top3 insulated (bta41) top3 (btb41) a2 a1 g rd91 (bta40) bta40, bta41 and btb41 series 2014-6-16 www.kersemi.com 1
table 3: absolute maximum ratings tables 4: electrical characteristics (t j = 25c, unless otherwise specified) table 5: static characteristics symbol parameter value unit i t(rms) rms on-state current (full sine wave) rd91 / top3 t c = 95c 40 a top ins. t c = 80c i tsm non repetitive surge peak on-state current (full cycle, t j initial = 25c) f = 50 hz t = 20 ms 400 a f = 60 hz t = 16.7 ms 420 i 2 ti 2 t value for fusing t p = 10 ms 880 a 2 s di/dt critical rate of rise of on-state cur- rent i g = 2 x i gt , t r 100 ns f = 120 hz t j = 125c 50 a/s v dsm /v rsm non repetitive surge peak off-state voltage t p = 10 ms t j = 25c v dsm /v rsm + 100 v i gm peak gate current t p = 20 s t j = 125c 8a p g(av) average gate power dissipation t j = 125c 1w t stg t j storage junction temperature range operating junction temperature range - 40 to + 150 - 40 to + 125 c symbol test conditions quadrant value unit i gt (1) v d = 12 v r l = 33 ? i - ii - iii iv max. 50 100 ma v gt all max. 1.3 v v gd v d = v drm r l = 3.3 k ? t j = 125c all min. 0.2 v i h (2) i t = 500 ma max. 80 ma i l i g = 1.2 i gt i - iii - iv max. 70 ma ii 160 dv/dt (2) v d = 67 %v drm gate open t j = 125c min. 500 v/s (dv/dt)c (2) (di/dt)c = 20 a/ms t j = 125c min. 10 v/s symbol test conditions value unit v t (2) i tm = 60 a t p = 380 s t j = 25c max. 1.55 v v t0 (2) threshold voltage t j = 125c max. 0.85 v r d (2) dynamic resistance t j = 125c max. 10 m ? i drm i rrm v drm = v rrm t j = 25c max. 5a t j = 125c 5ma note 1: minimum i gt is guaranted at 5% of i gt max. note 2: for both polarities of a2 referenced to a1. bta40, bta41 and btb41 series 2014-6-16 www.kersemi.com 2
table 6: thermal resistance symbol parameter value unit r th(j-c) junction to case (ac) rd91 (insulated) / top3 0.9 c/w top3 insulated 0.6 r th(j-a) junction to ambient top3 / top3 insulated 50 c/w s = copper surface under tab. figure 1: maximum power dissipation versus rms on-state current (full cycle) figure 2: rms on-state current versus case temperature (full cycle) figure 3: relative variation of thermal impedance versus pulse duration figure 4: on-state characteristics (maximum values) 0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 p(w) i (a) t(rms) 180 0 25 50 75 100 125 0 5 10 15 20 25 30 35 40 45 i (a) t(rms) t (c) c bta41 bta40 / btb41 = 180 1.e-03 1.e-02 1.e-01 1.e+00 1.e+01 1.e+02 1.e+03 1.e-03 1.e-02 1.e-01 1.e+00 k=[z /r th th ] t (s) p z bta / btb41 th(j-a) z th(j-c) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 1 10 100 400 i (a) tm v (v) tm t = 25c j . t max. v = 0.85v r = 10 m j to d ? t= j t max. j bta40, bta41 and btb41 series 2014-6-16 www.kersemi.com 3
figure 5: surge peak on-state current versus number of cycles figure 6: non-repetitive surge peak on-state current for a sinusoidal pulse with width t p < 10 ms and corresponding value of i 2 t figure 7: relative variation of gate trigger current, holding current and latching current versus junction temperature (typical values) figure 8: relative variation of critical rate of decrease of main current versus (dv/dt)c (typical values) figure 9: relative variation of critical rate of decrease of main current versus (dv/dt)c 1 10 100 1000 0 50 100 150 200 250 300 350 400 450 i (a) tsm number of cycles t=20ms one cycle non repetitive t initial=25c j repetitive t =70c c 0.01 0.10 1.00 10.00 100 1000 10000 i (a), i t (a s) tsm 22 t (ms) p t initial=25c j i tsm di/dt limitation: 50a/s i t 2 -40 -20 0 20 40 60 80 100 120 140 0.0 0.5 1.0 1.5 2.0 2.5 t (c) j i,i,i[t] / gt h l j i ,i ,i [t =25c] gt h l j i gt i h & i l 0.1 1.0 10.0 100.0 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (dv/dt)c (v/s) (di/dt)c [(dv/dt)c] / specified (di/dt)c 0 25 50 75 100 125 0 1 2 3 4 5 6 (di/dt)c [t ] / pecified] j (di/dt)c [t s j t (c) j bta40, bta41 and btb41 series 2014-6-16 www.kersemi.com 4
table 7: product selector figure 11: top3 (insulated and non insulated) package mechanical data part numbers voltage (xxx) sensitivity type package 600 v 800 v bta40-xxxb x x 50 ma standard rd91 bta41-xxxbrg x x 50 ma standard top3 ins. btb41-xxxbrg x x 50 ma standard top3 btb: non insulated top3 package bt a 40 - 600 b rg triac series insulation current voltage sensitivity and type packing mode a = insulated b = non insulated 40 = 40a in rd91 41 = 40a in top3 600 = 600v 800 = 800v b = 50ma standard rg = tube blank = bulk r h k g f e d b a c jj p ?l ref. dimensions millimeters inches min. typ. max. min. typ. max. a 4.4 4.6 0.173 0.181 b 1.45 1.55 0.057 0.061 c 14.35 15.60 0.565 0.614 d 0.5 0.7 0.020 0.028 e 2.7 2.9 0.106 0.114 f 15.8 16.5 0.622 0.650 g 20.4 21.1 0.815 0.831 h 15.1 15.5 0.594 0.610 j 5.4 5.65 0.213 0.222 k 3.4 3.65 0.134 0.144 ?l 4.08 4.17 0.161 0.164 p 1.20 1.40 0.047 0.055 r 4.60 0.181 bta40, bta41 and btb41 series figure 10: ordering information scheme 2014-6-16 www.kersemi.com 5
figure 12: rd91 package mechanical data a e3 n2 n1 b f i a1 b1 l1 a2 l2 b2 c c2 c1 ref. dimensions millimeters inches min. max. min. max. a 40.00 1.575 a1 29.90 30.30 1.177 1.193 a2 22.00 0.867 b 27.00 1.063 b1 13.50 16.50 0.531 0.650 b2 24.00 0.945 c 14.00 0.551 c1 3.50 0.138 c2 1.95 3.00 0.077 0.118 e3 0.70 0.90 0.027 0.035 f 4.00 4.50 0.157 0.177 i 11.20 13.60 0.441 0.535 l1 3.10 3.50 0.122 0.138 l2 1.70 1.90 0.067 0.075 n1 33 43 33 43 n2 28 38 28 38 table 8: ordering information ordering type marking package weight base qty delivery mode bta40-xxxb bta40xxxb rd91 20 g 25 bulk bta41-xxxbrg bta41xxxb top3 ins. 4.5 g 30 tube btb41-xxxbrg btb41xxxb top3 4.5 g 30 tube note: xxx = voltage table 9: revision history date revision description of changes sep-2003 5 last update. 25-mar-2005 6 top3 delivery mode changed from bulk to tube. 14-oct-2005 7 t c values for i t changed in table 3. ecopack statement added. bta40, bta41 and btb41 series 2014-6-16 www.kersemi.com 6
|